Won-Door™ DuraSound™ XL Specification
SECTION 10655 - Accordion Folding Partitions
PART 1- GENERAL
1.01 SUMMARY OF WORK
A. Division 0 and Division 1, as indexed, apply to this section.
B. Furnish and install all accordion-type folding partitions shown on
the drawing and specified herein.
1.02 RELATED SECTIONS
A. All headers, support structures, surrounding insulation, jambs, pocket
doors, field painting, blocking and wood trim as required shall be furnished
and installed by other sections.
[B. All electrical work including but not limited to the following electrical
work by Electrical Section:
1. Provide 115 / 230 volt single phase (or A.C.208 volt, 3-phase) electrical
service in conduit to the reversing magnetic starter.
2. Provide 115 / 230 volt single phase (or A.C.208 volt, 3-phase) electrical
service in conduit between the starter and the gear motor.
3. Provide 4"x4" electrical box for the key switch located within
line-of-sight of the folding partition.
4. Provide 3-conductor, 18 gauge stranded wire in conduit between the
key switch and starter.
5. Provide key switch for door operation (3 position switch, spring return
to center from right or left).]
1.03 QUALITY ASSURANCE
A. Installation shall be accomplished by factory trained personnel.
B. Sound rated partitions shall have the laboratorysound rating indicated,
when tested in accordance with the requirements of ASTM E-90.
1.04 SUBMITTALS
A. Refer to Section 01300-Shop drawings and Submittals
B. Indicate required stacking depth, pocket width, if applicable, and
height of header above finished floor. Show installation details
and layout [and electrical requirements].
1.05 DELIVERY, STORAGE AND HANDLING
A. Deliver to the job site in manufacturer's original, unopened package.
1.06 COORDINATION BY GENERAL CONTRACTOR
A. Coordinate the efforts of the various trades affected by the work of
the section. Assure accurate installation of header, jamb and trim. Provide
field dimensions for fabrication.
B. Supervise unloading and handling. Store boxes flat (not more than three
high) in a dry area and protect from elements that may damage materials.
Replace damaged materials at no additional cost to the owner.
[C. Permanent power shall be in place for final connection when partitions
are erected. Assure access to and proper clearance for motor operations.]
1.07 WARRANTY
A. Materials shall be warranted against defects and workmanship for a
period of one (1) year from date of substantial completion.
PART 2- PRODUCTS
2.01 MANUFACTURER
A. Folding partitions shall be DuraSound™ XL as manufactured by Won-Door™
Corporation, Salt Lake City, Utah.
2.02 MATERIALS
A. Operation: Shall be top supported and manually [electrically] operated.
B. Construction: Shall consist of two parallel, accordion-type walls of
panels independently suspended with no pantographs or interconnections
except at the lead-post.
C. Panels shall be formed of cold rolled vinyl-clad 24 gauge V-grooved
steel. Vinyl shall be permanently bonded by heat pressure lamination to
the steel panels. Panels shall be connected by full height extruded vinyl
hinges.
D. Insulation: interior surfaces of both walls shall be completely covered
with a continuous blanket of two (2) pounds density foil-backed fiberglass
fastened in place with steel spring-clips.
E. Suspension systems: Shall consist of two extruded aluminum tracks spaced
12" (.305) on center attached to the overhead structural support.
Each panel shall be suspendedby a steel hanger pin and a pair of 11&Mac218;2"
(.038) diameter nylon-tired ball bearing rollers. Each lead-post shall
be suspended by a 8-wheel ball bearing trolley.
F. Leadpost: Shall be of 16 gauge cold rolled steel and shall be connected
to the partition by specially formed steel panels. Lead-post hardware
shall include standard grip-type handles and a sliding latch to effect
closure. [Key locks shall be provided.]
G. Perimeter Seals: Shall consist of continuous extruded vinyl sweep strips
attached to the top and bottom of the partition. Leading edges of the
lead-posts and receiver posts shall be acoustically sealed by extruded
vinyl interlocking seals.
H. Hanging weight shall be 4.5 pounds per square foot.
I. Stabilizer Bar: Shall consist of a top supported internal diagonal
bracing member that insures proper alignment and latching of the leadpost
during operation.
2.03 ACOUSTICAL PERFORMANCE
A. Sound transmission class (STC) shall be 48 when tested in accordance
with requirements of ASTM E-90.
2.04 COLORS
A. Vinyl finish color shall be selected by the architect from manufacturer's
standard colors (M-885 White or ML-745 Teak).
2.05 MOTOR OPERATOR
A. Operation: Motor-operated folding partition shall be driven by means
of a roller chain attached to the stabilizer bar trolley. An internally
mounted stabilizer shall keep lead-posts plumb and in proper alignment
during operation and insure a tight fitting closure without the use of
mechanical latches.
B. Motor Operator Assembly: Shall consist of a 208 volt 3 phase A.C. gear
motor, [115 / 230 volt single-phase A.C. motor,] reversing electro-magnetic
starter, limit switch and key switch. Size of each motor shall be determined
by manufacturer to insure proper operation.]
PART 3-EXECUTION
3.01 PREPARATION BY GENERAL CONTRACTOR
A. Openings shall be to the dimensions specified, plumb and level.
B. Headers shall be leveled with the finished floor to within +/- 1/4"
(.006) tolerance over the entire length of the openings.
3.02 INSPECTION
A. Contractor shall inspect prepared opening and immediately notify the
architect, in writing, of any unacceptable conditions.
3.03 INSTALLATION
A. Install partitions in accordance with manufacturer's printed instruction.
B. Upon completion of the installation, the General Contractor shall protect
partitions from damage and replaceor repair subsequent damage so that
partitions are acceptable tothe architect, at no additional charge to
the owner.