Specifications for Won-Door™
products are available in a number of file formats. Select |
Using
FAST SPEC:
Step 1 - Choose the Category and Type that matches your application.
Step
2 - Click on the link for your copy in Adobe PDF format.
FireGuard™
20, 60, 90 and 180 minute.
If
your application exceeds the parameters below, please contact your local representative.
Category
1, Type 1: Single-parting, straight
If used for egress:
200 sq. ft. or less (one motor mounted in the pocket)
If used for non-egress:
201 sq. ft. to 300 sq. ft. (one motor mounted in the pocket)
Category 1, Type 2: Single-parting, curved
with one radius*
If used for egress:
160 sq. ft. or less (one motor mounted in the pocket)
If used for non-egress:
161 sq. ft. to 250 sq. ft. (one motor mounted in the pocket)
*Note: standard curves are 5' and 10' radius.
Category 1, Type 3: Bi-parting, straight
If used for egress:
160 sq. ft. or less (one motor mounted in the pocket)
161sq. ft. to 400 sq. ft. (two motors, one in each pocket)
If used for non-egress:
401 sq. ft. to 600 sq. ft. (two motors, one in each pocket)
Category 1, Type 4: Bi-parting, curved
If used for egress:
320 sq. ft. or less (two motors, one in each pocket)
If used for non-egress:
321 sq. ft. to 500 sq. ft. (two motors, one in each pocket)
FireGuard™
90TR (Temperature Rise)
If
your application exceeds the parameters below, please contact your local representative.
The TR model has been tested in accordance with the ASTM E-152 Standard for
fire doors for 90 minutes and has qualified for the "temperature rise"
label. Temperature rise labeled doors are currently required by the model
codes as opening protectives for penetrations in exit stairway enclosures
in non-sprinklered buildings. FireGuard™ TR doors are typically used
in exit stairways. Non-egress applications are not covered in FAST SPEC.
Category 2, Type 1: Single-parting, straight
If used for egress:
200 sq. ft. or less (one motor mounted in the pocket)
Category 2, Type 2: Single-parting, curved
with one radius*
If used for egress:
160 sq. ft. or less (one motor mounted in the pocket)
Category 2, Type 3: Bi-parting, straight
If used for egress:
160 sq. ft. or less (one motor mounted in the pocket)
161sq. ft. to 400 sq. ft. (two motors, one in each pocket)
Category 2, Type 4: Bi-parting, curved
If used for egress:
320 sq. ft. or less (two motors, one in each pocket)
|
||||||||||||||||||||||