U.S. Fire Test Reports
International Code Council
FM Approvals
FM – Certificate of Compliance
FM – Letter of Compliance
FM – Approval Guide Listing for FireGuard & FireGuard-G
FM – Approval Guide Listing for FireGuard-CS
UL Solutions
National, State & City Listings & Reports
International Fire Test Reports
United Kingdom – Warrington Fire Test
United Kingdom – Warrington Fire Test addendum
United Kingdom – Warrington Fire Test Photos
Canada – UL – 10B Certificate of Compliance
Australia – CSIRO Fire Test
SS 489: 2001 – Assessment by Warrington Fire; WF Report No: 165721
BS 476: Part 22, Two-Hour Non-Insulated Fire Rating, Part I
BS 476: Part 22, Two-Hour Non-Insulated Fire Rating, Part II
SS 489: 2001, Two-Hour Non-Insulated Fire Rating, Part I
SS 489: 2001, Two-Hour Non-Insulated Fire Rating, Part II
Chinese Fire Test
UAR Fire Test
Other Letters, Reports & Certifications
The Fundamentals of Fire Code and Egress Requirements During Schematic Design Guide brings together many of the most useful charts and requirements of the IBC including Occupancy Types, Area Allowances, Travel Distances and Construction Types.
Complying horizontal sliding fire doors may be used in place of side-hinged swing doors in a Means of Egress (in other than Group H occupancies). The Won-Door FireGuard fire door meets all performance criteria for horizontal sliding fire doors when used in a Means of Egress as set forth in the International Building Code (IBC), NPFA 101 Life Safety Code, and NFPA 80 Standard for Fire Doors and Other Protective Openings.
IBC NFPA 101 Life Safety Code NFPA 80 Standard for Fire Doors and 2012 2012 NFPA 101 Life 2013 Chapter 9 2015 Section 1010.1.4.3 Special purpose horizontal sliding, accordion 2015 Section 2016 Chapter 2018 Section 2018 Section 7.2.1.14 Special-Purpose Horizontally Sliding 2019 Chapter 9 2021 Section 1010.3.3 Special purpose horizontal sliding, accordion or 2021 Section 2022 Chapter
Application IBC 2012 Reference IBC 2015 Reference IBC 2018 Reference IBC 2021 Reference Area separation Area Allowance Section 503, Section 504, Table 504.3 Section 506, Table 506.2 Section 504, Table 504.3 Section 506, Table 506.2 Section 504, Table 504.3 Section 506, Table 506.2 Occupancy separation Mixed occupancy – accessory use Section Section Section Section Mixed occupancy – Section 508.3; Table Section Section Section Vertical Opening Separation
Non-egress Sections Sections Sections Sections Shaft enclosure – escalator Section Section 712.1.3 Section Section Atrium Section 404 Section 404 Section 404 Section 404 Vertical exit enclosure Section 1022 Section 1023 Section 1023 Section 1023 Corridor Separation Retail Section 1014 Section 1016 Section 1016 Section 1016 Healthcare (Group Sections 407.2 & Sections 407.2 & Sections 407.2 & Sections 407.2 & Exit Access Separation Horizontal exit Section 1025 Section 1026 Section 1026 Section 1026 Exit passageway Section 1023 Section 1024 Section 1024 Section 1024 Pedestrian walkway Section 3104 Section 3104 Section 3104 Section 3104 Elevator Separation Elevator lobby Section 713.14.1 Section 3006 Section 3006 Section 3006 Elevator smoke & draft Section exception 3 Sections 713.14 Sections 713.14 Sections 713.4 Smoke Group I-2 Section 407.5 Section 407.5 Section 407.5 Section 407.5 Smoke & draft 716.5.3.1 716.5.3.1 716.5.3.1 716.2.2.1.1 716.5.3.1 716.2.2.1.1 Opening Protection In fire walls Section 706.8 Section 706.8 Section 706.8 Section 706.8 In fire barriers Section 707.6 Section 707.6 Section 707.6 Section 707.6 In fire partitions Section 708.6 Section 708.6 Section 708.6 Section 708.6 In smoke barrier walls Section 709.5 Section 709.5 Section 709.5 Section 709.5 In smoke partition Section 710.5 Section 710.5 Section 710.5 Section 710.5 In smoke control systems Section Section Section 909.5.3 Section In temperature rise Section 716.5.5 Section 716.5.5 Section 716.2.2.3 Section 716.2.2.3 Oversize doors Section Section Section Section Means of Egress Door Swing Section 1008.1.2 exception 6 Section 1010.1.2 exception 6 Section 1010.1.2 exception 6 Section 1010.1.2 exception 6 Performance Section 1008.1.4.3 Section 1010.1.4.3 Section 1010.1.4.3 Section 1010.3.3 Emergency and Standby Power Systems Standby power Section Section Section Section
Application NFPA 101 2012 Reference NFPA 101 2015 Reference NFPA 101 2018 Reference NFPA 101 2021 Reference Means Door Swing exception 7.2.1.4.1 7.2.1.4.1 7.2.1.4.1 7.2.1.4.1 In Emergency, Slide 7.2.1.9.1.7 7.2.1.9.1.7 7.2.1.9.10 7.2.1.9.1.10 Subdivided space with not less than 2 means of egress 7.2.1.12.2 7.2.1.12.2 7.2.1.12.2 7.2.1.12.2 Performance 7.2.1.14 7.2.1.14 7.2.1.14 7.2.1.13 Fire Barriers Door assemblies in 7.2.4.3.7 7.2.4.3.7 7.2.4.3.7 7.2.4.3.7 Smoke Partitions and Barriers Doors in Smoke 8.4.3.2 8.4.3.2 8.4.3.2 8.4.3.2 Doors in Smoke Barriers complying with 8.5.4.4 8.5.4.4 8.5.4.4 8.5.4.4 Assembly 7.2.1 Complying Doors (new occupancies) 12.2.2.2.1 12.2.2.2.1 12.2.2.2.1 12.2.2.2.1 7.2.1 Complying Doors (existing occupancies) 13.2.2.2.1 13.2.2.2.1 13.2.2.2.1 13.2.2.2.1 Educational Occupancies 7.2.1 Complying Doors (new occupancies) 14.2.2.2.1 14.2.2.2.1 14.2.2.2.1 14.2.2.2.1 7.2.1 Complying Doors (existing 15.2.2.2.1 15.2.2.2.1 15.2.2.2.1 15.2.2.2.1 Day-Care 7.2.1 Complying doors (new occupancies) 16.2.2.2.1 16.2.2.2.1 16.2.2.2.1 16.2.2.2.1 7.2.1 Complying doors (existing occupancies) 17.2.2.2.1 17.2.2.2.1 17.2.2.2.1 17.2.2.2.1 Health Care Occupancies 7.2.1 Complying 18.2.2.2.1 18.2.2.2.1 18.2.2.2.1 18.2.2.2.1 7.2.1 Complying doors (existing occupancies) 19.2.2.2.1 19.2.2.2.1 19.2.2.2.1 19.2.2.2.1 Non-automatic doors 18.2.2.2.10.1 18.2.2.2.11.1 18.2.2.2.11.1 18.2.2.2.11.1 Non-automatic doors (existing occupancies) 19.2.2.2.10.1 19.2.2.2.11.1 19.2.2.2.11.1 19.2.2.2.11.1 Horizontal Exit 18.2.2.5.3 (2) 18.2.2.5.3 (2) 18.2.2.5.3 (2) 18.2.2.5.3 (2) Horizontal Exit (existing occupancies) 19.2.2.5.4(2) 19.2.2.5.4(2) 19.2.2.5.4 19.2.2.5.4 Horizontal exit (8 18.2.2.5.4 18.2.2.5.4 18.2.2.5.4 18.2.2.5.4 Horizontal exit (6 ft or more) (double egress swing door) 18.2.2.5.5 18.2.2.5.5 18.2.2.5.5 18.2.2.5.5 Cross-corridor 18.3.7.6 (2) 18.3.7.6 (2) 18.3.7.6 (2) 18.3.7.6 (2) 8ft minimum corridor width clear opening of 6 ft 11 in 18.3.7.6 18.3.7.6 18.3.7.6 18.3.7.6 6ft minimum 18.3.7.6 (5)(b) 18.3.7.6 (5)(b) 18.3.7.6 (5)(b) 18.3.7.6 (5)(b) Openings in Smoke Barriers 19.3.7.9 (2) 19.3.7.9 (2) 19.3.7.9 (2) 19.3.7.9 (2) Ambulatory 7.2.1 Complying Doors (new occupancies) 20.2.2.2.1 20.2.2.2.1 20.2.2.2.1 20.2.2.2.1 7.2.1 Complying 21.2.2.2.1 21.2.2.2.1 21.2.2.2.1 21.2.2.2.1 Detention and Correctional Occupancies 7.2.1 Complying 22.2.2.2 22.2.2.2 22.2.2.2 22.2.2.2 7.2.1 Complying Doors (existing occupancies) 23.2.2.2 23.2.2.2 23.2.2.2 23.2.2.2 Lodging Automatic closing, smoke- and fire-resisting doors 26.3.1.1.1.2 26.3.1.1.1.2 26.3.1.1.1.2 26.3.1.1.1.2 Hotels 7.2.1 Complying Doors (new occupancies) 28.2.2.2.1 28.2.2.2.1 28.2.2.2.1 28.2.2.2.1 7.2.1 Complying 29.2.2.2.1 29.2.2.2.1 29.2.2.2.1 29.2.2.2.1 Apartment Buildings 7.2.1 Complying 30.2.2.2.1 30.2.2.2.1 30.2.2.2.1 30.2.2.2.1 7.2.1 Complying Doors (existing occupancies) 31.2.2.2.1 31.2.2.2.1 31.2.2.2.1 31.2.2.2.1 Residential 7.2.1 Complying Doors (new occupancies) 32.3.2.2.2 32.3.2.2.2 32.3.2.2.2 32.3.2.2.2 7.2.1 Complying 33.3.2.2.2 (1) 33.3.2.2.2 (1) 33.3.2.2.2 (1) 33.3.2.2.2 (1) Cross-corridor openings in smoke barriers 32.3.3.7.15 32.3.3.7.15 32.3.3.7.16 32.3.3.7.14 Mercantile 7.2.1 Complying Doors (new occupancies) 36.2.2.2.1 36.2.2.2.1 36.2.2.2.1 36.2.2.2.1 7.2.1 Complying 37.2.2.2.1 37.2.2.2.1 37.2.2.2.1 37.2.2.2.1 Business Occupancies 7.2.1 Complying 38.2.2.2.1 38.2.2.2.1 38.2.2.2.1 38.2.2.2.1 7.2.1 Complying Doors (existing occupancies) 39.2.2.2.1 39.2.2.2.1 39.2.2.2.1 39.2.2.2.1 Industrial 7.2.1 Complying Doors 40.2.2.2.1 40.2.2.2.1 40.2.2.2.1 40.2.2.2.1 Storage 7.2.1 Complying Doors 42.2.2.2.1 42.2.2.2.1 42.2.2.2.1 42.2.2.2.1 7.2.1 Complying 42.8.2.2.2.1 42.8.2.2.2.1 42.8.2.2.2.1 42.8.2.2.2.1 Appendix
Not considered A.7.2.1.9 A.7.2.1.9 A.7.2.1.9 A.7.2.1.9
Other Protective Openings
Section 1008.1.4.3 Horizontal sliding
fire doors
Safety Code Section 7.2.1.14 Horizontal-Sliding Door Assemblies
Special-Purpose Horizontally sliding Accordion or Folding Doors and Chapter 5
Care and Maintenance.
or folding doors.
7.2.1.14 Special-Purpose
Horizontally Sliding Accordion or Folding Door Assemblies.
9 Special-Purpose Horizontally Sliding Accordion or Folding Doors and Chapter
5 Inspection, Testing and Maintenance.
1010.1.4.3 Special purpose horizontal sliding, accordion or folding doors.
Accordion or Folding Door Assemblies.
Special-Purpose Horizontally Sliding Accordion or Folding Doors and Chapter 5
Inspection, Testing and Maintenance.
folding doors.
7.2.1.13 Special-Purpose
Horizontally Sliding Accordion or Folding Door Assemblies.
9 Special-Purpose Horizontally Sliding Accordion or Folding Doors and Chapter
5 Inspection, Testing and Maintenance.
Table 503
508.2.4;
508.2.4
508.2.4
508.2.4
separation vs non-separation
508.4
508.3; Table 508.4
508.3; Table 508.4
508.3; Table 508.4
communicating stairs
712.1.8 & 712.1.12
712.1.9 & 712.1.12
712.1.9 & 712.1.12
712.1.9 & 712.1.12
712.1.3
712.1.3
712.1.3
I-2)
407.3
407.3
407.3
407.3
& tunnel
713.14.1
item 3 & 3006.3 exception 3
item 3 & 3006.3 exception 3
item 3 & 3006.3 exception 3
Compartmentation
control
walls
909.5.2
909.5.3
909.5.3
applications
716.5.7.2
716.5.7.2
716.5.7.2
716.2.9.2
Criteria
2702.2.7
2702.2.10 (50 cycles)
2702.2.17 (50 cycles)
2702.2.18 (50 cycles)
of Egress
(4)(b)
(4)(b)
(4)(b)
(4)(b)
to Open
Criteria
Fire Barrier horizontal exits
Partitions complying with 7.2.1
7.2.1
Occupancies
occupancies)
Occupancies
doors (new occupancies)
(new occupancies)
(new occupancies)
(2)
(2)
ft or more) (double egress swing door)
smoke barriers
(5)(a)
(5)(a)
(5)(a)
(5)(a)
corridor width clear opening of 64 in
Health Care Occupancies
Doors (existing occupancies)
Doors (new occupancies)
or Rooming Houses
and Dormitories
Doors (existing occupancies)
Doors (new occupancies)
Board and Care Occupancies
(1)
(1)
(1)
(1)
Doors (existing occupancies)
Occupancies
Doors (existing occupancies)
Doors (new occupancies)
Occupancies
Occupancies
Doors (parking structures)
powered doors subject to 7.2.1.9